Specifications
Installation and Operation Manual Chapter 4 API Reference
MiRIC-E1, MiRIC-T1 Ver. 1.5 Parameters 4-5
Status Parameters
The following status parameters are available for reading:
• Loss of Rx signal (LOS)
• Alarm indication signal (AIS)
• Yellow alarm (T1 only).
Table 4-2. Status Parameters
Index R/W Description
0x3E8 R 1= Active 0 = Inactive
Digit 0 = LOS (Loss of Rx signal)
Digit 1 = Don’t care
Digit 2 = AIS (Alarm indication signal)
Digit 3 = Yellow alarm (T1 only)
Configuration Parameters
Configure the following parameters:
• TLB0 (T1 only), Transmit line build out
• Framed or Unframed
• Line code:
HDB3 or AMI for E1 and B8ZS or AMI for T1
AMI
• Clock, Rx clock or internal clock
• Data transmitted or not transmitted on timeslot 16 (E1 only)
• Framing D4 or ESF (T1) or CRC enabled or disabled (E1).
Table 4-3 on the following page describes the configuration parameters.