Specifications
Chapter 4 Configuration Installation and Operation Manual
4-30 Configuring RICi-622GE for Operation RICi-622GE Ver. 1.0
RICi-622GE
Configuration>Logical Layer>VCAT
1. VCG (VCG-1)
2. Administrative Status (Up)
3. VC Type (STS-3C)
4. Number of VCs [1 – 8] (4)
5. Encapsulation (GFP)
6. VCAT (Yes)
7. VCG Name (Put your string here)
8. GFP >
>
ESC-prev. menu; !-main menu; &-exit 1 M/2 C
Figure
4-37. VCG Menu Default Configuration, SONET
³ To activate a VCG:
1. From the VCG menu (Configuration > Logical Layer > VCAT), type f to navigate
to the screen for a non-active VCG.
The VCG menu is displayed, showing a VCG with Administrative Status set
to Down, and undefined VC type.
RICi-622GE
Configuration>Logical Layer>VCAT
1. VCG (VCG-2)
2. Administrative Status (Down)
3. VC Type (-)
4. Encapsulation (GFP)
5. VCAT (Yes)
6. VCG Name … (Put your string here)
7. GFP >
>
ESC-prev. menu; !-main menu; &-exit 1 M/2 C
Figure
4-38. VCG Menu for Non-active VCG
2. Select Administrative Status and set it to Up to activate the VCG.
3. Configure the rest of the parameters as desired, according to
Table
4-8
.
4. Type % to update the database with your changes.