Specifications

Chapter 4 Configuration Installation and Operation Manual
4-22 Configuring RICi-622GE for Operation RICi-622GE Ver. 1.0
Parameter Description Values
SD Threshold
Selects the Bit Error Rate (BER) value that
if exceeded results in the generation of
the signal degraded alarm
10
-6
, 10
-7
, 10
-8
, 10
-9
J1 path trace Specifies the J1 path trace label
Alphanumeric string of up to 15
characters. If fewer than 15 characters
are typed, the Padding parameter is used
to pad the path trace label
Padding
Defines the type of characters used to
pad the path trace label, when it is shorter
than the required length of 15 characters
NULL – Null characters
Spaces – Space characters
Block Rx on TIM
Defines whether to block the traffic if
Trace Identifier Mismatch (TIM) occurs
Enable – Block the traffic on path trace
mismatch
Disable – Do not block the traffic on
path trace mismatch
RDI on TIM
Defines the sending of Remote Defect
Indication (RDI) if Trace Identifier
Mismatch (TIM) occurs
Enable – Send RDI if TIM occurs
Disable – Do not send RDI if TIM occurs
RDI on PLM
Defines the sending of Remote Defect
Indication (RDI) if Payload Label Mismatch
(PLM) occurs
Enable – Send RDI if PLMoccurs
Disable – Do not send RDI if PLM occurs
³ To configure SDH/SONET port LVC parameters:
1. From the SDH/SONET LVC VCAT menu (Configuration > Physical Layer >
SONET/SDH > LVC > VCAT), select the VCG to configure.
2. Configure the parameters as detailed in
Table
4-4.
RICi-622GE
Configuration>Physical layer>SDH/SONET>LVC>VCAT
1. VCG (VCG-1)
2. Payload Label [0 – ff] (02)
3. EED Threshold (1E-3)
4. SD Threshold (1E-6)
5. Path trace (rici622ge)
6. Padding > (NULL)
7. Block Rx on TIM (Disable)
8. RDI on TIM (Disable)
9. RDI on PLM (Disable)
%-Db Update; #-Undo; F - Forward
ESC-prev. menu; !-main menu; &-exit 1 M/2 C
Figure
4-27. SDH/SONET LVC Menu