Specifications
Installation and Operation Manual Chapter 4 Configuration
RICi-622GE Ver. 1.0 Configuring RICi-622GE for Operation 4-21
Parameter Description Values
SD Threshold Selects the BER value that if exceeded results
in the generation of the signal degraded alarm
10
-6
, 10
-7
, 10
-8
, 10
-9
RDI on Fail Defines the sending of Remote Defect
Indication (RDI) if the link fails
Enable – Send RDI if link fails
Disable – Do not send RDI if link fails
ALS Enables/disables the automatic laser shutdown
(ALS) function. The ALS function automatically
switches off the transmitter of a regenerator
section in case of cable break
Enable – ALS function is enabled
Disable – ALS function is disabled
³ To configure SDH/SONET port HVC parameters:
1. From the SDH/SONET HVC menu (Configuration > Physical Layer > SONET/SDH
> HVC), select the link, VC4/STS3, and STS-1 to configure.
2. Configure the parameters as detailed in
Table
4-3.
RICi-622GE
Configuration>Physical layer>SDH/SONET>HVC
Link [1-2] > (1)
VC-4\STS3 [1-4] (01)
1. Payload Label [0 – ff] (02)
2. EED Threshold (1E-3)
3. SD Threshold (1E-6)
4. J1 path trace (rici622ge)
5. Padding > (Spaces)
6. Block Rx on TIM (Disable)
7. RDI on TIM (Disable)
8. RDI on PLM (Disable)
F - Forward ;
ESC-prev. menu; !-main menu; &-exit 1 M/2 C
Figure
4-26. SDH/SONET HVC Menu
Table
4-3. SDH/SONET HVC Parameters
Parameter Description Values
Payload Label
Defines the payload label to attach to
packets
00 - FF
EED Threshold
Defines the Bit Error Rate (BER) value that
if exceeded results in the generation of
the error rate degradation alarm
10
-3
, 10
-4
, 10
-5