Specifications
Chapter 4 Configuration Installation and Operation Manual
4-20 Configuring RICi-622GE for Operation RICi-622GE Ver. 1.0
RICi-622GE
Configuration>Physical layer>SDH/SONET
1. Frame type > (SDH)
2. Interface >
3. Mapping >
4. HVC >
5. LVC >
6. APS >
7. Tx Clock Source >
>
ESC-prev. menu; !-main menu; &-exit 1 M/2 C
Figure
4-24. SDH/SONET Menu
³ To configure SDH/SONET port interface parameters:
1. From the SDH/SONET Interface menu (Configuration > Physical Layer >
SONET/SDH > Interface), select the link to configure.
2. Configure the parameters as detailed in
Table
4-2.
RICi-622GE
Configuration>Physical layer>SDH/SONET>Interface
1. Link [1-2] … (1)
2. Administrative Status (Up)
3. EED Threshold (1E-3)
4. SD Threshold (1E-5)
5. RDI on Fail (Disable)
6. ALS (Enable)
>
F - Forward ;
ESC-prev. menu; !-main menu; &-exit 1 M/2 C
Figure
4-25. SDH/SONET Interface Menu
Table
4-2. SDH/SONET Interface Parameters
Parameter Description Values
Administrative
Status
Defines whether port is available for operation.
Up – SDH/SONET port is enabled
Down –SDH/SONET port is disabled
EED Threshold Defines the BER value that if exceeded results
in the generation of the error rate degradation
alarm
10
-3
, 10
-4
, 10
-5