Specifications

Installation and Operation Manual Chapter 4 Configuration
RICi-622GE Ver. 1.0 Configuring RICi-622GE for Management 4-15
Special rules apply to the su (superuser) user name. If connection to the RADIUS
server is lost, RICi-622GE uses its internal authentication database for the user
verification and allows login for the superuser.
Enable Remote Local – RICi-622GE uses authentication database stored at
the RADIUS server to check if the entered user name and password match
the data server records. If no user name record is found or a password
does not match user name, RICi-622GE uses its internal authentication
database.
You must set the RADIUS server IP address in the RADIUS parameters menu
before you can enable RADIUS authentication.
Configuring Control Port Parameters
RICi-622GE management software allows you to configure the control port
parameters, which include specifying the terminal data rate, data bits, parity,
stop bits, and security timeout.
³ To configure the control port parameters:
From the Control Port menu (Main > Configuration > System > Control Port),
do the following:
Select Baud Rate to specify the data rate (permitted values are 9600 bps;
19,200 bps; or 115,200 bps).
Select Data bits to specify the data bits (7 or 8)
Select Parity to specify the parity (None, Odd, or Even)
Select Stop Bits to specify the stop bits (NA, 1, 1.5, or 2)
Select Terminal and then Security Timeout to specify the number of minutes
to keep a ConfiguRAD or Terminal session active when there is no user input
(1–60).
RICi-622GE
Configuration>System>Control Port
1. Set Baud Rate (Bps) > (115200 bps)
2. Data bits > (8)
3. Parity > (None)
4. Stop bits > (1)
5. Terminal >
>
ESC-prev. menu; !-main menu; &-exit 1 M/2 C
Figure
4-17. Control Port Menu
Note
Note