Specifications

Installation and Operation Manual Chapter 3 Operation
RICi-622GE Ver. 1.0 Configuration and Management Alternatives 3-7
Remote inband management via the first user port. Remote management is
performed using Telnet, ConfiguRAD (RAD’s Web-based application), or an
SNMP-based management system).
The RICi-622GE management software supports the following functions:
Viewing system information
Modifying configuration parameters and modes of operation, including
setting system default values and resetting the unit
Monitoring RICi-622GE performance
Initiating connectivity tests
Uploading and downloading software and configuration files.
Working with Terminal
RICi-622GE has a V.24/RS-232 asynchronous DCE port, designated CONTROL and
terminated in a 9-pin D-type female connector. The control port continuously
monitors the incoming data stream and immediately responds to any input string
received through this port.
The RICi-622GE control port can be configured to communicate at the following
rates: 9.6, 19.2, or 115.2 kbps.
³ To start a terminal control session:
1. Make sure all RICi-622GE cables and connectors are properly connected.
2. Connect RICi-622GE to a PC equipped with an ASCII terminal emulation
application (for example, Windows Hyper Terminal or Procomm).
3. Turn on the control terminal PC and set its port parameters to:
115,200 baud, 8 bits/character, 1 stop bit, no parity, flow control: none.
4. Set the terminal emulator to ANSI VT100 emulation (for optimal view of
system menus).
5. If you are using Hyper Terminal, set the terminal mode to 132 column mode
for optimal view of system menus
(Properties->Settings->Terminal Setup->132 column mode).
6. When the initialization and self-test are over, press any key to display the
login screen.
RICi-622GE
USER NAME:
PASSWORD:
ESC – clear; & – exit; 0 M/2 C
Figure
3-3. Login Screen