Specifications

Chapter 2 Installation and Setup Installation and Operation Manual
2-6 Connecting to Power RICi-622GE Ver. 1.0
Connect RICi-622GE to a network interface card using a cross cable.
When connecting Fast Ethernet cables longer than 30 meters (98 feet), it is
recommended to use shielded cables.
Figure
2-6: Fast Ethernet Management Connector
2.9 Connecting to Power
Before connecting or disconnecting any communication cable, the unit must be
grounded by connecting its power cord to a power outlet with a ground terminal,
and by connecting the ground terminal on the panel (if provided) to a protective
ground.
Any interruption of the protective (grounding) conductor (inside or outside the
instrument) or disconnecting of the protective ground terminal can make this
unit dangerous. Intentional interruption is prohibited.
RICi-622GE is equipped with a laser diode.
Please observe the following precautions:
Before turning on the equipment, make sure that the fiber optic cable is intact
and is connected to the transmitter.
Do not look into a laser connector when the power is turned on, a laser can
cause eye damage.
Do not use broken or unterminated fiber-optic cables/connectors.
ATTENTION: The laser beam may be invisible!
The unit cannot be connected simultaneously to both AC and DC outlets.
Connecting to AC Power
AC power is supplied to RICi-622GE via 1.5m (5 ft) standard power cable
terminated by standard 3-prong plug. The cable is provided with the unit.
³ To connect AC power:
1. Verify that the AC outlet is grounded properly. Ensure that the supply voltage
is in the range 100 VAC to 240 VAC.
Warning
Warning
Warning
Note