Specifications
Installation and Operation Manual Chapter 2 Installation and Setup
RICi-622GE Ver. 1.0 Connecting to Management Stations 2-5
Figure
2-4: SDH/SONET SFP Connectors
2.8 Connecting to Management Stations
RICi-622GE can be connected to a local ASCII terminal via the CONTROL port or to
a remote network management station via the dedicated Ethernet management
port.
Connecting to an ASCII Terminal
RICi-622GE is connected to an ASCII terminal via a 9-pin D-type female connector
designated CONTROL. Refer to
Appendix A
for the connector pinout.
³ To connect to an ASCII terminal:
1. Connect the male 9-pin D-type connector of CBL-DB9F-DB9M-STR straight
cable available from RAD to the CONTROL connector.
2. Connect the other connector of the CBL-DB9F-DB9M-STR cable to an ASCII
terminal.
Terminal cables must have a frame ground connection. Use ungrounded cables
when connecting a supervisory terminal to a DC-powered unit with floating
ground. Using improper terminal cable may result in damage to supervisory
terminal port.
Figure
2-5: CONTROL Connector
Connecting to a Network Management Station
RICi-622GE is connected to an NMS via an 8-pin RJ-45 connector designated
ETH MNG. Refer to
Appendix A
for the connector pinout.
³ To connect to an NMS:
• Connect RICi-622GE to a hub or switch using a straight cable
or
Caution