Specifications

Chapter 2 Installation and Setup Installation and Operation Manual
2-4 Connecting to SDH/SONET Equipment RICi-622GE Ver. 1.0
2.6 Connecting to Gigabit Ethernet Equipment
RICi-622GE includes two Gigabit Ethernet ports.
RICi-622GE is connected to the Gigabit Ethernet equipment via fiber optic SFP or
8-pin RJ-45 electrical port. Refer to
Appendix A
for the RJ-45 connector pinout.
The Gigabit Ethernet ports must be either both fiber optic interface or both
electrical interface.
³ To connect to the Gigabit Ethernet equipment with fiber optic SFP:
Connect RICi-622GE to the Gigabit Ethernet network equipment using a
standard fiber optic cable terminated with an LC connector. Refer to
Installing
Fiber Optic SFP Modules
for details on installing fiber optic SFPs.
Figure
2-2: Gigabit Ethernet SFP Connectors
³ To connect to the Gigabit Ethernet equipment with a copper interface:
Connect RICi-622GE to the Gigabit Ethernet network equipment using a
standard straight UTP/STP cable terminated with an RJ-45 connector.
When connecting Gigabit Ethernet cables longer than 30 meters (98 feet), it is
recommended to use shielded cables.
Figure
2-3: Gigabit Ethernet 10/100/1000BaseT Electrical Connectors
2.7 Connecting to SDH/SONET Equipment
RICi-622GE is connected to the SDH/SONET equipment via fiber optic SFP
interface, with LC connector.
³ To connect to the SDH/SONET network equipment :
Connect RICi-622GE to the SDH/SONET network equipment using a standard
fiber optic cable terminated with an LC connector, as necessary. Refer to
Installing Fiber Optic SFP Modules
for details on installing fiber optic SFPs.
Note