Specifications

Chapter 2 Installation and Setup Installation and Operation Manual
2-2 Mounting the Unit RICi-622GE Ver. 1.0
least 15 cm at rear of the unit, for cable connections and ventilation. For proper
ventilation, keep at least 4 cm clearance from the sides and top of the product.
The ambient operating temperature of RICi-622GE is 0°
to 55° C (32° to 131°F), at
a relative humidity of up to 90%, non-condensing.
Do not cover fan and ventilation openings.
2.2 Package Contents
RICi-622GE package contains the following items:
RICi-622GE unit
SFP modules (if ordered)
Two AC power cords (for AC option)
Two DC connection kits (for DC option)
CBL-DB9F-DB9M-STR straight cable for ASCII terminal connection (if ordered)
RM-34 (if ordered) for mounting one 19-inch RICi-622GE unit in a
19-inch rack
RM-34-23 (if ordered) for mounting one 23-inch RICi-622GE unit in a
23-inch rack
WM-34 (if ordered) for mounting one 19-inch RICi-622GE unit on the wall.
2.3 Required Equipment
RICi-622GE requires no special tools for installation. You need a screwdriver to
mount RICi-622GE in a 19-inch or 23-inch rack. You need a screwdriver and drill
to mount RICi-622GE on the wall.
2.4 Mounting the Unit
RICi-622GE is designed for installation as a desktop unit or mounted in a rack.
For rack-mounting instructions, refer to the installation kit manual.
If RICi-622GE is to be used as a desktop unit, place and secure the unit on a
stable, non-movable surface.
Refer to the clearance and temperature requirements in
Site Requirements and
Prerequisites.
Warning