Specifications
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual
6-20 Handling Alarms and Traps RICi-622GE Ver. 1.0
Code Message
Default
Severity
Interpretation
79 PAYLOAD LABEL UNEQUIPPED Minor The specified VCG has received an unequipped signal label.
This alarm condition may often occur while a new trail is
being prepared
80 PATH TRACE ID MISMATCH (TIM) Minor The path trace ID received from the far end for the specified
VCG does not match the expected value. This may indicate
incorrect routing of the corresponding VC or VT.
81 PAYLOAD LABEL MISMATCH (PLM) Minor
A
payload label mismatch has been detected for the specified
VCG. This may indicate incorrect routing of the corresponding
VC or VT.
This alarm condition may often occur while a new trail is
being prepared
82 REMOTE DEFECT INDICATION(RDI) Minor RDI (remote defect indication) is received through the
specified VCG
83 SIGNAL DEGRADED ERROR Minor The bit error rate of the signal received through the specified
VC or VT exceeds the preset signal-degraded threshold
84 EXCESSIVE BIT ERROR RATE Minor The bit error rate of the signal received through the specified
VC or VT exceeds the preset excessive BER threshold
85 JITTER BUFFER OVERFLOW Event The specified jitter buffer has reported an overflow event
86 RESET OCCURRED Event RICi-622GE has been reset
85 Reserved for future use
88 CABLE TYPE MISMATCH Major The cable type connected to the E1 port connector is not
suitable for the configured interface type.
Check and correct in accordance with the equipment
connected to the port connector
89 VC AIS OCCURRED Major The Alarm Indication Signal (AIS indication) has been received
through the Signal Label (C2) byte of the specified
VC-4/STS-1
90 to
96
Reserved for future use
97 SFP FAILURE Major The SFP module has been removed, or has failed
98 FAR END CSF ERROR Major Far end CSF indication (detection of a CSF indication),
displayed by ports with Fault Propagation enabled.
This condition is cleared on receipt of the first valid GFP client
data frame, or after failing to receive 3 CSF indications in
3 seconds
99 RESET TO ACTIVATE NEW SOFTWARE Major The alarm appears (ON state) after software download has
been successfully completed, but RICi-622GE has not yet
been reset.
It disappears (OFF state) after resetting or restarting
RICi-622GE
100 TX DEGRADE(LASER TEMPERATURE) Major The SFP laser temperature monitor reports a value that
exceeds the high alarm threshold
101 CLOCK OUT OF RANGE Major The frequency of the timing reference clock is not within the
allowed range
102 POWER SUPPLY 2 FAILURE Major RICi-622GE reports failure of power supply module 2. Replace
this power supply module