Specifications
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual
6-16 Handling Alarms and Traps RICi-622GE Ver. 1.0
RICi-622GE
Monitoring>System>All Alarms
Code Port Description Severity State Count
86 RESET OCCURRED Event On 1
14 LINK-1 SIGNAL LOSS Major On 1
89 L1 STS1-3 VC AIS OCCURRED Major On 1
50 ETH-02 LAN NOT CONNECTED Major On 1
64 VCG-1 GFP OUT OF SYNC Major On 1
103 VCG-1 RX TRAIL FAILURE Major On 1
14 L1 SOH SIGNAL LOSS Major Off 2
34 L1 SOH FRAME LOSS Major Off 2
>
ESC-prev.menu; !-main menu; &-exit ?-help 1 M/2 C
Figure
6-20. All Alarms
Table
6-6. Alarm Parameters
Parameter Meaning Values
Code Code assigned to alarm Refer to
Table
6-7
for a description of
alarm codes.
Port Port for which alarm is active 1…max num of ports
Description Description of alarm
State State of alarm On , Off
Severity Severity of alarm Critical, Major, Minor
Count Number of times alarm occurred 1 .. Max Times
Table
6-7
describes the alarm messages generated by RICi-622GE. The alarm
messages are listed in ascending order of their codes.
Table
6-7. Alarm Messages
Code Message
Default
Severity
Interpretation
1 POWER SUPPLY 1 FAILURE Major RICi-622GE reports failure of power supply module 1. Replace
this power supply module.
2 ALARM BUFFER OVERFLOW Major More than 255 alarms have been received, and therefore the
new alarms are overwriting the oldest alarms (the first
alarms) stored in the alarm buffer. Read the alarms and then
clear the buffer
3 HARDWARE FAILURE Major A technical failure has been detected. Replace RICi-622GE
4 Reserved for future use
5 CLOCK CHANGE TO FALLBACK Event RICi-622GE has switched to the fallback clock source