Specifications

Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics
RICi-622GE Ver. 1.0 Monitoring Performance 6-9
RICi-622GE
Monitoring>Physical Layer>SDH/SONET >Statistics >SOH-1
ES SES UAS(SEFS) CV Elapsed Time
Current Interval 0 0 366 0 00:06:06
Interval 1 0 0 900 0 00:15:00
Interval 2 0 0 699 0 00:15:00
Interval 3 0 0 0 0 00:15:00
Interval 4 0 0 194 0 00:15:00
Interval 5 0 0 20 0 00:15:00
Interval 6 0 0 43 0 00:15:00
Interval 7 0 0 900 0 00:15:00
Interval 8 0 0 900 0 00:15:00
Interval 9 0 0 900 0 00:15:00
Interval 10 0 0 891 0 00:15:00
F-Forward; C-Clear Statistics
ESC-prev. menu; !-main menu; &-exit 1 M/2 C
Figure
6-12. SDH/SONET SOH Statistics
³ To display the SDH/SONET statistics for HVC:
1. From the Monitoring SDH/SONET menu (Monitoring > Physical Layer >
Statistics > SDH/SONET), select HVC to show the HVC statistics screen for
HVC-1-1 (
Figure
6-13
).
Table
6-3
describes the SDH/SONET statistic counters.
2. Type f to advance to the statistics for HVC-1-2, HVC-1-3, HVC-1-4.
RICi-622GE
Monitoring>Physical Layer>SDH/SONET >Statistics >HVC-1-1
ES SES UAS(SEFS) CV Elapsed Time
Current Interval 0 0 825 0 00:13:45
Interval 1 0 900 0 0 00:15:00
Interval 2 0 699 0 0 00:15:00
Interval 3 0 0 0 0 00:15:00
Interval 4 0 200 1 0 00:15:00
Interval 5 0 900 0 0 00:15:00
Interval 6 0 900 0 0 00:15:00
Interval 7 0 900 0 0 00:15:00
Interval 8 0 900 0 0 00:15:00
Interval 9 0 900 0 0 00:15:00
Interval 10 0 891 0 0 00:15:00
F-Forward; C-Clear Statistics
ESC-prev. menu; !-main menu; &-exit 1 M/2 C
Figure
6-13. SDH/SONET HVC Statistics
³ To display the SDH/SONET statistics for LVC:
1. From the Monitoring SDH/SONET menu (Monitoring > Physical Layer >
Statistics > SDH/SONET), select LVC.