Specifications

Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics
RICi-622GE Ver. 1.0 Monitoring Performance 6-5
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Alarm that caused switchover
Possible values (hexadecimal):
0 – No alarm
6 – Wait to restore
0A– Signal degradation low priority
0B – Signal degradation high priority
0C – Signal failure low priority
0D – Signal failure high priority
0E – Forced switchover
Primary link as configured in
Configuration> Physical layer >
SDH/SONET > APS
Possible values:
0 – Link-1
1 – Link-2
Figure
6-7. K1 Byte Layout
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Currently active link
Possible values:
0 – Link-1
1 – Link-2
Reserved for future use
(always set to 4)
Figure
6-8. K2 Byte Layout
Displaying Timing Source
RICi-622GE allows you to view the timing source reference.
³ To display the timing status:
1. From the Monitoring Physical Layer menu (Main > Monitoring >
Physical Layer), select Timing.
The Timing status menu appears.
Table
6-1
details the timing parameters.
2. Select the port for which you wish to view the timing.
RICi-622GE
Monitoring>Physical layer>Timing
Tx Clock Source > (LINK 1)
Port > > (INK 1)
Rx SSM > > (UNKNOWN)
Tx SSM > > (DNU)
ESC-prev.menu; !-main menu; &-exit 1 M/2 C
Figure
6-9. Timing Status Menu
Table
6-1. Timing Parameters
Parameter Description
Tx Clock Source Displays the transmit clock reference