This chapter provides detailed instructions for setting up typical applications
using RICi-622GE units. Refer to
Chapter 4
for a detailed description of all
configuration options available for RICi-622GE.
5.1 Configuring a Point-to-Point Application
Figure
5-1
illustrates a point-to-point application of Ethernet private line over
SDH/SONET.
Figure
5-1. Point-to-Point Ethernet Private Line over SDH/SONET
In this application, RICi-622GE (A) receives Ethernet user traffic separated by
VLAN at both Gigabit Ethernet user ports, and transmits it over separate VLANs
through the SDH/SONET network. RICi-622GE (B) receives SDH/SONET user traffic
separated by VLAN, and transmits it via one Gigabit Ethernet user port, separated
by VLAN.
You must configure the following to deploy RICi-622GE units in this application:
1. System parameters (host IP, default gateway)
2. Bridge parameters
3. Flows.
The default logical layer and mapping configuration of one VCG containing four
VCs of type VC-4/STS-3c, each VC mapped to a separate VC-4/STS-3 of
SDH/SONET link 1, is sufficient for this application.
Table
5-1. System Configuration Summary, Point-to-Point Application
Device Host IP IP mask Default Gateway
RICi-622GE (A) 192.168.10.10 255.255.255.0 192.168.10.1
RICi-622GE (B) 192.168.10.20 255.255.255.0 192.168.10.1