Specifications
Installation and Operation Manual Chapter 4 Configuration
RICi-622GE Ver. 1.0 Additional Tasks 4-53
• Reset all parameters to default settings, except for management-related
parameters
• Overall reset of the device.
Returning to Factory Defaults
The factory default option allows you to reset the system parameters to factory
default values. You can reset all system parameters, or just the system
parameters that are not related to management.
³ To return to factory default values:
1. From the System menu (Configuration > System), select Factory Default.
The Reset to Factory Default screen appears.
RICi-622GE
Configuration> System > Factory Default
1. Full
2. Except Management Connectivity Parameters
>
ESC-prev. menu; !-main menu; &-exit 1 M/2 C
Figure
4-63. Factory Default Menu
2. Select which type of reset you would like:
Full reset of all parameters
Reset of parameters excluding management-related parameters.
After you select the reset type, a confirmation message appears.
The device will restart. Do you want to proceed? (Y/N)
3. Type Y to confirm or N to cancel.
If you type Y, the device is reset to factory default values as specified,
and then reboots automatically.
Resetting the RICi-622GE Unit
RICi-622GE offers the option of performing an overall reset.
³ To reset RICi-622GE:
1. From the System menu, select Reset Device.
A confirmation message appears.
Are you sure you want to reset device (Y/N)?
2. Type Y to confirm or N to cancel.
If you type Y, the device resets, and then reboots.