System information
Chapter 4 Configuring Typical Applications User’s Manual
4-6 Configuring Optimux-34 Optimux-34 Ver. 2.81
Parameter Possible Values / Remarks
Clock Source Internal
LBT
Changing the Clock Source from Internal to LBT takes about 2 minutes. A
confirmation message is displayed announcing “Changing Clock Source to LBT
may take about 2 minutes”, click <OK> or <Cancel> to acknowledge.
Read-Write for the Local device
Configuring SNMP
You can configure SNMP settings to specify the management station(s) that can
transmit or receive Optimux-34 traps.
To configure SNMP:
1. On the menu bar, click Options > Manager List (see
Figure 3-4
).
Figure 4-5. Manager List Dialog Box
2. Change the IP addresses, as required.
3. You can elect not to send traps to a selected address by clearing the relevant
Send Traps check box adjacent to that address.
4. Click <Set> to implement the change.