System information

User’s Manual Chapter 3 Configuration Management
Optimux-34 Ver. 2.81 Configuring Operational Parameters 3-5
Parameter Possible Values / Remarks
Redundancy The availability of redundancy on the local/remote device.
Available
Not Available
Read-Only
Redundancy Mode The redundancy manner of operation:
Off
Auto
Manual
Read-Write
If the Redundancy Mode is set to ‘Manual’, you should manually request the
SNMP agent to configure the optSelectLink to ‘Main’ or ‘Back’ after the link has
switched from main to backup because when the Redundancy Mode is set to
‘Manual’ it means that there was a problem on the main that has been just fixed.
Note: This parameter is available only when the device has two links and
Redundancy is available.
Default Main Link Link A
Link B
Read-Write
Link Active Link A
Link B
Read-Only
Clock Source Internal
LBT
Changing the Clock Source from Internal to LBT takes about 2 minutes. A
confirmation message is displayed announcing “Changing Clock Source to LBT
may take about 2 minutes”, click <OK> or <Cancel> to acknowledge.
Read-Write for the Local device
If the Remote device is disconnected, the fields concerning the remote device will
be displayed as“ - - “ (N/A value).
3.2 Configuring Operational Parameters
This section discusses how to manage Optimux-34 ports for operation using
RADview/TDM Optimux-34.
Managing ports includes the following tasks:
Selecting the port
Viewing and modifying port parameters, including:
E1 port parameters
Not
e