System information
Chapter 2 Installation and Operation User’s Manual
2-10 Using the Graphical User Interface (GUI) Optimux-34 Ver. 2.81
Table 2-4. Port Status Indicators
Port Color Description
Magenta Errors exist MNG-ETH
Gray No errors exist and no tests are
running
Magenta Errors exist USER-ETH
Gray No errors exist and no tests are
running
Magenta When line status experiences Loss of
Signal or any other failure
Blue The loopback test is running.
E1
Gray (in all other cases) If the line status has no alarm
Magenta When line status experiences Loss of
Signal or any other failure
Blue The loopback test is running.
V.35
Gray (in all other cases) If the line status has no alarm
Magenta When line status experiences Loss of
Signal or any other failure
Blue The loopback test is running.
E3 Link
Gray (in all other cases) When line status experiences no alarm
When a port may contain several statuses, only the most severe status color is
displayed. (Magenta is most severe, then blue, then gray.)
Agent Status Indicators
The Optimux version name on the front panel of both Local and Remote devices
are framed with a thin colored frame in green, white, or red. This frame indicates
the agent status, as summarized in
Table 2-5
below.
Figure 2-16. Agent Status Indicator
Note