Specifications

Chapter 4 Supervisory Port Software Configuration Optimux-XLT1 Installation and Operation Manual
4-10 The Optimux-XLT1 Interface
The tributaries and fiber optic settings can be set from the terminal (see Changing
the Configuration of the Interface on page 4-10). The applicable tributaries and
fiber optic interface states are indicated in Table 4-3.
Table 4-3. T1 and Fiber Optic Interface States
State Indicates
No loop No loop is set
Local loop A local loop is set. An T1 local loop applies to all ports of an T1 module (see
Troubleshooting Instructions on page 5-3 for details)
Remote loop A remote loop is set. A T1 remote loop applies to a single port of a T1 module (see
Troubleshooting Instructions on page 5-3 for details). Remote loop on fiber optic link is
not available.
The Ethernet port is set from a DIP switch. The applicable settings are:
Table 4-4. Ethernet Setting
Setting Indicates
Half duplex Ethernet port operates in half duplex
Full duplex Ethernet port operates in full duplex
Changing the Configuration of the Interface
To change the configuration of the monitor interface:
4. Type 3 in the Interface Menu screen.
The Change Interface Configuration screen appears.
LOCAL DEVICE
CHANGE INTERFACE CONFIGURATION
------------------------------
NOTE: To change the configuration of the interface, select it
in the next format:
- decimal number from 1 to 5 for modules,
(1 for module A, 2 for module B,..., 5 for E3 link)
- decimal number from 1 to 4 for ports
- for E3 link port=1 selects main link, port=2 selects backup link.
0. Exit
1. Module module A
2. Port port 1
3. Test Configuration Filter enabled
Enter your choice:
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com