Specifications

Optimux-XLT1 Installation and Operation Manual Chapter 4 Supervisory Port Software Configuration
The Optimux-XLT1 Interface 4-9
The interface ports are characterized by the states indicated in Table 4-2.
Table 4-2. Interface Ports
State Indicates
No port The interface module associated with the specific port is not installed or the port number is
irrelevant for a certain type of interface module. For example, only a single port is
associated with an Ethernet interface module.
O.K. The signal is detected at the input of an T1 or fiber optic port or, for an Ethernet port, link
integrity pulse is detected on the receive pair.
Signal Loss No signal is detected at the input of an T1 or fiber optic port or, for an Ethernet port, link
integrity pulse is not detected on the receive pair.
AIS An Alarm Indication Signal was detected at the input of an T1 port or on the fiber optic link.
NA Not relevant
The first row in the screen table specifies the type of module installed in the
Optimux-XLT1 slot. For example, 4T1_UTP in slot B specifies a 4-port balanced T1
module.
For the HS interface, the state is always characterized as NA.
Viewing Configuration of Monitor Interface
To view the configuration of the monitor interface:
Type 2 in the Interface Menu screen.
The Monitor Interface Configuration screen appears.
LOCAL DEVICE
MONITOR INTERFACE CONFIGURATION
-------------------------------
-----------------------------------------------------------------------------
| Port | Module A | Module B | Module C | Module D | FO link |
| number | ETHERNET | NO_MODULE | NO_MODULE | NO_MODULE | F/O-F/O |
-----------------------------------------------------------------------------
| 1 | Filter en | No port | No port | No port | No loop |
-----------------------------------------------------------------------------
| 2 | No port | No port | No port | No port | No loop |
-----------------------------------------------------------------------------
| 3 | No port | No port | No port | No port |
-----------------------------------------------------------------------------
| 4 | No port | No port | No port | No port |
-----------------------------------------------------------------------------
0.Exit
Enter your choice: