Specifications

Optimux-XLT1 Installation and Operation Manual Chapter 4 Supervisory Port Software Configuration
The Optimux-XLT1 Device Information 4-7
Changing the Clock Source
To change the clock source:
Type 4 in the Device Information Menu screen.
The Clock screen appears.
LOCAL DEVICE
CLOCK
-----
0. Exit
1. Change clock source: INTERNAL
2. Reset to default configuration
Enter your choice:
To view and change the clock source:
1. Type 1 to enter the change clock source option.
2. Type 1 for LoopBackTiming (RCV clk), 2 for Internal (INT clk), or 0 to cancel
your choice.
To reset to the default clock configuration (INT):
1. Type 2 to perform the reset to default configuration option.
2. Confirm the action.
3. Type 0 to exit the Clock screen.
Option 1 (view and change the clock source) is not available in Hardware Version A.
Loop back timing is not available at the Remote Device and at the Local Device at
the same time.
Note