Specifications
Chapter 4 Supervisory Port Software Configuration Optimux-XLT1 Installation and Operation Manual
4-6 The Optimux-XLT1 Device Information
Setting Link-Redundancy
➤ To change the link-redundancy setting:
1. Type 3 in the Device Information Menu screen.
The Change Link Redundancy screen appears.
LOCAL DEVICE
CHANGE LINK REDUNDANCY
----------------------
0. Exit.
1. Redundancy status AVAILABLE
2. Redundancy setup MANUAL
Enter your choice:
2. Type 2 to enter the redundancy setup.
3. Type 1 for AUTOMATIC, 2 for MANUAL, 3 for OFF, or press ESC to cancel
your choice.
4. To exit to the screen, type 0.
1. Redundancy status is not available for changes, but you can change
Redundancy status even if the status is "NOT AVAILABLE". (And in that case your
change will take place once the status "AVAILABLE").
2. When in normal operation, the link redundancy setting must be changed only
after the system has been operating and synchronized for 120 sec on the same
link.
3. Changes to the link redundancy mode take affect up to 120 seconds after being
made.
4. Before synchronizing two Optimux-XLT1 units, the link redundancy mode of
both units must be the same.
Notes
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com