Specifications

Chapter 3 Operation Optimux-XLT1 Installation and Operation Manual
3-6 Operating Instructions
Redundancy Functions
The redundant power supply and the redundant link module ensure the
Optimux-XLT1 operation even when one of these critical modules fails.
Link Redundancy
When the redundant link is installed (backup module and link A) and the link-
redundancy is set to AUTOMATIC from the terminal or SNMP, the Optimux-XLT1
starts using the main link. It will automatically switch to the backup link when the
main link fails (signal loss/sync loss). The LINK A/B SYNC LOSS LED on the front
panel indicates the deactivated link. If the failure is due to signal loss, the
Optimux-XLT1 will switch back to the main link, when the signal is recovered in
the main link. If the failure is due to sync loss, the backup link becomes the active
link until signal loss/sync loss occurs on the backup link.
When the redundant link is installed and the management link-redundancy is
MANUAL, the Optimux-XLT1 starts using the main link. It will automatically switch
to the backup link when the main link fails (signal loss/sync loss). The LINK A/B
SYNC LOSS LED on the front panel indicates the deactivated link. The backup link
remains active even when the main link recovers. Switching back to the main link
is performed by setting the link-redundancy to AUTOMATIC from the terminal or
by turning the system OFF and then ON.
When the management link-redundancy is OFF, the redundancy function is not
available.
Power Supply Redundancy
In the redundant power supply mode, both supplies share the Optimux-XLT1
power consumption. If one of the power supply modules fails, the entire power
consumption of the unit is automatically drawn from a single power supply. In this
case, the respective PWR LED on the front panel indicates the active power
supply.
All changes made to the terminal or SNMP in link redundancy mode at the local site
automatically affect the remote site.
Turn OFF
Set the Optimux-XLT1 rear power switch (switches) to OFF.