Table 2-2. Internal Settings
Identification of
Internal Setting
Function Settings Factory Setting
Main Board
J1 through J10 MNG-ETH port is available from
front or rear panel
Port A – The MNG-ETH port is
only available from the front panel
in half-duplex only and operates as
an Ethernet port.
Separate – The MNG-ETH port is
available from the rear panel in
half-duplex. The MNG-ETH port on
the front panel operates as an
Ethernet port, is combined into a
fiber optic link and is available in
half or full duplex.
Separate
J11 Setting unit to work with one or
two power supplies
ON – When the unit uses two
power supplies.
OFF – When the unit uses only one
power supply.
To match
numbered order
of power supplies
JP5 To facilitate clock from the T1
module to the station clock module
Jumper connected
Jumper disconnected
Jumper
disconnected
ETH–TOP card
SW1 The ETH-TOP card mounted on the main board supports the fixed Ethernet port of the
Optimux-XLT1 unit. A similar switch mounted on the Ethernet module installed in slots B, C
and D supports the optional Ethernet ports (up to three).
Section 1 Determines the transmission mode
of the Ethernet ports in slots B, C
and D, and in the fixed Ethernet
port, either full or half duplex (if J1
through J10 are set to Port A, the
working mode of the fixed Ethernet
port must be half-duplex only).
ON – Full duplex
OFF – Half duplex
OFF
Section 2 Enables and disables data
throughput compression
ON – Enable
OFF – Disable
ON
Section 3 Determines whether all frames are
transmitted over the WAN or only
those that are destined for another
LAN. If this section is set to OFF,
the software selects the filtering
mode.
ON – Filtered
OFF – Not filtered
OFF
Section 4 Not used in the Optimux-XLT1
current version and should be set
to the default position specified in
Figure 2-2.
ON
OFF
OFF