Specifications
Optimux-XLT1 Installation and Operation Manual Chapter 2 Installation and Setup
Installation and Setup 2-5
➤ To reach the internal switches and jumpers:
1. Disconnect all the cables connected to the Optimux-XLT1.
2. Unscrew two captive screws on each side of the unit and eight captive screws
on the top.
3. Remove the unit cover.
4. Set switches and jumpers of the installed modules as specified below.
J11
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
JP1
JP1
SW1
ON
SW1
ON
SW1
SW1
SW2
SW2
JP1 ON T1 MODULES: 4T1/BAL
B8ZS
AMI
LINE CODE SET TO B8ZS
LINE CODE SET TO AMI
FACTORY SETTING: B8ZS
SW1 ON T1 MODULES: 4T1/BAL
ON - T1 CHANNEL ALARMS ARE
ENABLED
OFF - T1 CHANNEL ALARMS
ARE DISABLED
FACTORY SETTING: ON
1
ON
2 3 4
J1 TO J10 ON OPTI-E1/LAN
BOARD
PORT A - MNG-ETH
FROM FRONT
SEPERATE - MNG-ETH
FROM BACK
FACTORY SETTING:
separate
J11 ON OPTI-E1/LAN BOARD AND
ON ETH MODULE
ON - UNIT HAS 2 CONNECTED
POWER SUPPLIES
OFF - UNIT HAS ONLY 1 CONNECTED
POWER SUPPLY
FACTORY SET ACCORDING TO NUMBER
OF ORDERED POWER SUPPLIES
SW1 ON ETH-TOP CARD
ON - FULL-DUPLEX ETHERNET
OFF - COMPRESSION IS DISABLED
OFF - ALL FRAMES ARE
TRANSMITTED OVER WAN
(FACTORY PRESET)
OFF - HALF-DUPLEX ETHERNET
(FACTORY PRESET)
ON - COMPRESSION IS ACTIVATED
(FACTORY PRESET)
ON - ONLY FRAMES DESTI NED
FOR ANOTHER LAN ARE
TRANSMITTED OVER WAN
ON
1
ON
2
ON
3
FACTORY PRESET
(DO NOT CHANGE)
ON
4
FACTORY PRESE T
(SW2-1)
SW2 ON T1 MODULES: 4T1/BAL
1
ON
2 3 4
SW2-1 SW2-2 SW2-3 SW2-4 RANGE
ON
ON
ON
ON
ON
ON ON
ON
ON
ON
OFF OFF
OFF
OFF
OFF
NOT
CONNECTED
0-133 ft
133-266 ft
266-399 ft
399-533 ft
533-655 ft
DECLARES THE SHAPE AND AMPLITUDE
OF THE T1 TRANSMIT PULSE
Figure 2-2. Setting the Optimux-XLT1 Switches and Jumpers