Specifications
Installation and Operation Manual Chapter 5 Monitoring and Diagnostics
Optimux-34 Ver. 2.81 Monitoring Performance 5-3
Monitoring>System>Event Log
Source Alarm Status Severity
1 LOC device PS A FAIL ON MAJOR
2 LOC MNG-ETH Integrity Loss ON MAJOR
| 3 LOC device Redundancy not available ON MAJOR
V 4 LOC port 1 Signal Loss ON MAJOR
5 LOC port 2 Signal Loss ON MAJOR
6 LOC port 3 Signal Loss ON MAJOR
7 LOC port 4 Signal Loss ON MAJOR
8 LOC port 6 Signal Loss ON MAJOR
9 LOC port 7 Signal Loss ON MAJOR
10 LOC port 8 Signal Loss ON MAJOR
->>
>
ESC-prev.menu; !-main menu; &-exit; ?-help 1 user(s)
Figure
5-3. Event Log Screen
There can be up to 200 entries stored in the log file.
System Status
³ To view the system status:
• From the System menu, select Status.
The Status screen is displayed.
Monitoring>System>Status
1. Device Number > (Local)
Device Type > (Optimux-34)
Force Link > (LINK A)
Active Link > (LINK A)
Redundancy mode > (AUTO)
Redundancy status > (Available)
Clock source > (Internal)
PS A Status > (OK)
PS B Status > (Not mounted)
Alarm indication > (Major)
Test indication > (Off)
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
5-4. Status Screen
• Device Number - The Optimux-34 device number. The number is configurable
if connected to a remote device and not configurable when Optimux-34 is not
connected to a remote device or when the remote device is not an Optimux
device. The device number is always visible with one of the following values:
Local (default)
Remote.