Specifications
Chapter 4 Configuration Installation and Operation Manual
4-18 Performing Additional Tasks Optimux-34 Ver. 2.81
Field Description Possible Values Visibility
Alarms Masks Tributary alarms
Masked
Unmasked
Administrative
Status (Up)
2. Select the Device Number option to set the device to Local or Remote.
3. Select Administrative Status option and set the status to Up or Down.
4. Select Port Name to set a name for the port.
5. Select Clock Source to set Internal or LBT (Loopback Timing) or External
timing.
6. Select the DCD option to set the interface to Permanent ON or Control.
7. Select the CTS option to set the interface to Permanent ON or Control.
8. Select the DTE Loop Detection to mask or unmask DTE Loops.
9. Select Alarms to mask or unmask the V.35 alarms.
4.3 Performing Additional Tasks
Setting the User Name and Password
To enhance security, you can specify a user name and password to control access
to the Optimux-34 management functions.
³ To set user name and password:
1. Follow the path: System > Management > Management Access > User Access.
The User Access menu is displayed.
2. From the User Access menu, select Change Password.
The Change Password screen is displayed.
3. To change the password, select Password and then enter the new password.
The new password may contain up to eight characters.
Configuration>System>Management>Management Access>User Access
>Change password
1. User name … ()
2. Password … (****)
3. New password … (****)
4. Confirm new password …
Please Confirm New Password (Up To 8 Characters)
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
4-19. Change Access Menu