Specifications

Installation and Operation Manual Chapter 4 Configuration
Optimux-34 Ver. 2.81 Configuring Optimux-34 for Operation 4-17
³ To configure the V.35 port:
1. From the Configuration menu, select Physical Layer> V.35.
The V.35 menu is displayed.
Configuration>Physical Layer>V.35
1. Device Number > (Local)
2. Administrative Status (Up)
3. Port name ... ()
4. Clock Source > (Internal)
5. DCD Status > (Permanent ON)
6. CTS Status > (Permanent ON)
7. DTE Loop Detection > (Disable)
8. Alarms (Unmasked)
>
Please select item <1 to 8>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
4-18. V.35 Menu
Table
4-14
describes the V.35 fields in the menu (see
Figure
4-18
).
Table
4-14. V.35 Values
Field Description Possible Values Visibility
Device Number The device number Remote
Local
Always
Administrative
Status
Port status Up
Down
Always
Port Name Sets a name for the port containing up to 15
characters.
Administrative
Status (Up)
Clock Source Configures the interface Clock Source
Internal
LBT
External
Administrative
Status (Up)
DCD Status Configures the interface DCD Status
When set to CONTROL, the DCD signal is set to
ON when the active link is good (no signal loss,
frame loss or AIS)
Permanent ON
Control
Administrative
Status (Up)
CTS Status Configures the interface CTS Status
When set to CONTROL, the CTS signal is set ON
when RTS is ON.
Permanent ON
Control
Administrative
Status (Up)
DTE Loop
Detection
Configures the interface DTE Loop Detection
When set to Enable, loops originated by DTE are
enabled.
Enable
Disable
Administrative
Status (Up)