Specifications

Chapter 4 Configuration Installation and Operation Manual
4-16 Configuring Optimux-34 for Operation Optimux-34 Ver. 2.81
Configuration>Physical Layer>E1
1. Device Number > (Local)
2. Port Number[1-16] ... (1)
3. Administrative Status (Up)
4. Port Name ... ()
5. Interface Type (Balance (120ohm))
6. Alarms (Unmasked)
>
Please select item <1 to 6>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
4-17. E1 Menu
Table
4-13
describes the E1 fields in the menu (see
Figure
4-17
).
Table
4-13. E1 Values
Field Description Possible Values Visibility
Device Number The device number Remote
Local
Always
Port Number E1 port number 1 to 16 Always
Administrative Status Port status
Up
Down
Always
Port Name Sets a name for the port containing up to
15 characters.
Administrative
Status (Up)
Interface Type Configures the interface to balance or
unbalance
Unbalance (75Ω)
Balance (120Ω)
Administrative
Status (Up)
Alarms Masks Tributary alarms
Masked
Unmasked
Administrative
Status (Up)
2. Select the Device Number option to set the device to either Local or Remote.
3. Select Port Number to set the E1 port number.
4. Select Administrative Status and set the status to either Up or Down.
5. Select Port Name to set a name for the port.
6. Select Interface Type and set to either Balance (120Ω) or Unbalance (75Ω).
Configure the channels in groups of eight only: Channels 1-8 or 9-16 only.
7. Select Alarms to mask or unmask the E1 alarms.
Configuring the V.35 Port
The V.35 option in the Physical Layer menu is for the configuration of the V.35
ports.