Specifications

Chapter 4 Configuration Installation and Operation Manual
4-12 Configuring Optimux-34 for Operation Optimux-34 Ver. 2.81
The Redundancy menu is displayed.
The Remote Redundancy option is available only when the Optimux-34 is
connected to a remote device.
³ To configure redundancy on the Optimux-34 or the active link:
1. From the Redundancy menu, select Local/Remote Redundancy.
The Local Redundancy menu is displayed.
Configuration>System>Local Redundancy
1. Force Link > (LINK A)
2. Mode > (AUTO)
>
Please select item <1 to 2>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
4-12. Local Redundancy Menu
Table
4-10
describes the Force Link and Mode fields in the Local/Remote
Redundancy menu (see
Figure
4-12
).
Table
4-10. Local/Remote Redundancy Values
Field Description Possible Values Visibility
Force Link The active link
LINK A
LINK B
Always
Mode The redundancy mode
Auto
Manual
Off
Always
2. Select Force Link to select Link A or Link B as the main link.
3. From the Local/Remote Redundancy menu, select Mode.
The Mode menu is displayed.
Configuration>System>Local Redundancy>Mode (AUTO)
1. AUTO
2. MANUAL
3. OFF
>
Please select item <1 to 3>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
4-13. Redundancy Mode Menu
Note