Specifications

Installation and Operation Manual Chapter 4 Configuration
Optimux-34 Ver. 2.81 Configuring Optimux-34 for Operation 4-9
The Control Port menu is displayed.
Configuration>System>Control Port
1. Baud Rate > (115200bps)
2. Security Timeout > (10min)
3. Pop Alarms > (OFF)
>
Please select item <1 to 3>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
4-9. Control Port Menu
Table
4-8
describes the Baud Rate, Security Timeout and Pop Alarms fields in the
Control Port menu (see
Figure
4-9
).
Table
4-8. Control Port Values
Field Description Possible Values Visibility
Baud Rate Terminal baud rate 9600 bps
19200 bps
38400 bps
57600 bps
115200 bps
Always
Security
Timeout
Gives an indication to exit the terminal after 10
minutes when a key is not pressed
Off
10 min
Always
Pop Alarms Displays the changes in the alarms on the lower
part of the terminal screen
On
Off
Always
2. From the Control Port menu, select Baud Rate.
The Baud Rate menu is displayed.
Configuration>System>Control Port>Baud Rate (115200 bps)
1. 9600 bps
2. 19200 bps
3. 38400 bps
4. 57600 bps
5. 115200 bps
>
Please select item <1 to 5>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
4-10. Baud Rate Menu
3. Choose the baud rate that matches your management terminal device.