Specifications

Chapter 4 Configuration Installation and Operation Manual
4-4 Configuring Optimux-34 for Operation Optimux-34 Ver. 2.81
³ To set device information:
1. From the System menu, choose Management.
The Management menu is displayed.
Configuration>System>Management
1. Device Information >
2. Host >
3. Managers List []>
4. Management Access >
5. Remote Management Access (High)
>
Please select item <1 to 5>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
4-4. Management Menu
Table
4-3
describes the Remote Management Rate field in the Management menu
(see
Figure
4-4
).
Table
4-3. Management Values
Field Description Possible Values Visibility
Remote
Management
Access
Management of the remote device. Devices
version 6.0 and before, the rate has to be set
to Low (300 bps). The rate has to be set to
High (1.2 kbps) for new devices.
Low (on Factory default)
High
Always
2. Select Device Information.
The Device Information menu is displayed.
The
Description
line identifies the device, along with the current hardware
and software version numbers.
Configuration>System>Management>Device Information
Description … (Optimux-34 HW Version:1.00/B, SW Version:2.81)
1. Name … (Optimux)
2. Location … (The location of this device)
3. Contact … (Name of contact person)
4. Serial number … ()
>
Please select item <1 to 4>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
4-5. Device Information Menu
3. To define a contact person, choose Contact and then enter the name, phone
and/or other details you want to save in this field, see
Figure
4-5
.