Specifications
Installation and Operation Manual Chapter 4 Configuration
Optimux-34 Ver. 2.81 Configuring Optimux-34 for Operation 4-3
Optimux-34
Configuration>System>Clock Source
1. Local Source > (Internal)
2. Remote Source > (Loopback Timing)
>
Please select item <1 to 2>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
4-2. Clock Source Menu
Table
4-2
describes the Local and Remote Source fields in the Clock Source menu
(see
Figure
4-2
).
Table
4-2. Clock Source Values
Field Description Possible Values Visibility
Local Source Local device clock souce
Internal
Loopback Timing
Always
Remote Source Remote device clock souce
Internal
Loopback Timing
When connected to a
remote device
•
The Remote Source option is available only when the Optimux-34 is connected
to a remote device.
•
After resetting to the default values, the clock configuration is INTERNAL.
2. From the Clock Source menu, choose either Local Source or Remote Source.
The Local Source menu is displayed.
Optimux-34
Configuration>System>Clock Source>Local Source (Internal)
1. Internal
2. Loopback Timing
>
Please select item <1 to 2>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
4-3. Local Source Menu
3. Choose either Internal timing or Loopback Timing).
Setting the Device Information
Each Optimux-34 unit can be configured to retain information about the unit,
such as its location and a name to easily identify the unit on the network.
Notes