Specifications

Chapter 3 Operation Installation and Operation Manual
3-2 Optimux-34 Controls and Indicators Optimux-34 Ver. 2.81
Figure
3-2. Typical 2U-high Front Panel with Optional Alarm and V.35 Connectors
Table
3-1. Optimux-34 Front Panel Controls and Indicators
Name Type State Function
PS A Indicator OFF Indicates that the unit is not powered
ON (green) Indicates that power supply A is ON and operates normally
ON (red) Indicates that a malfunction was detected in PS A or it is not
powered on. If PS B is installed Optimux-34 will continue to
operate normally.
PS B Indicator OFF Indicates that the unit is not powered
ON (green) Indicates that power supply B is ON and operates normally
ON (red) Indicates that a malfunction was detected in PS B or it is not
powered on. If PS A is installed Optimux-34 will continue to
operate normally.
SYSTEM TST Indicator ON (yellow) Indicates that the system is on loop test.
Blinking (yellow) Indicates that the system is during Auto baud detect process.
SYSTEM FLT Indicator ON (red) Indicates a control system fault or a failure detected during the
turn ON self test.
LINK A SYNC LOSS Indicator ON (red) Indicates that a loss-of-signal has been detected on the main
link.
Blinking (red) Indicates that in Manual Redundancy mode, LINK A is the main
link and is available but the signal is received from the backup
link (LINK B)
LINK A AIS Indicator ON (yellow) Indicates that an alarm indication signaling has been detected
on the link
LINK B SYNC LOSS Indicator ON (red) Indicates that a loss-of-signal has been detected on the backup
link
Blinking (red) Indicates that in Manual Redundancy mode LINK B is the main
link and is available but the signal is received from the backup
link (LINK A)
LINK B AIS Indicator ON (yellow) Indicates that an alarm indication signaling has been detected
on the backup link