Specifications
Installation and Operation Manual Chapter 2 Installation and Setup
Optimux-34 Ver. 2.81 Connecting to Power 2-7
Table
2-5. Management Port Options
Interface Connector Type Note maximum cable length
RS-232 9-pin D-type 16m (50 ft) for a 115 kbps data rate
MNG-ETH RJ-45 100m for a UTP cable, type 5
2.7 Connecting to Power
The Optimux-34 chassis ground is connected to the protective ground (middle)
pin of the power connectors, for the universal power supply version of the unit.
Intentional disconnection of the protective ground is prohibited since such an
action may expose personnel to electrical shock hazards.
Before connecting or disconnecting any communication cable, the unit must be
earthed by connecting its power cord to a power outlet with an earth terminal,
and by connecting the earth terminal on the panel (if provided) to a protective
earth.
Any interruption of the protective (grounding) conductor (inside or outside the
instrument) or disconnecting of the protective earth terminal can make this unit
dangerous. Intentional interruption is prohibited.
For the universal power supply ratings, refer to the
Site Requirements and
Prerequisites
section in this chapter.
Connecting to AC Power
AC power is supplied to the Optimux-34 through a standard 3-prong plug.
AC power should be supplied via a 1.5m (5 ft) standard power cable terminated
by a standard 3-prong socket. A cable is provided with the unit.
³ To connect to AC power:
1. Connect the power cable to the power connector on the Optimux-34 front panel.
2. Connect the power cable to the mains outlet.
The unit will turn on automatically upon connection to the mains.
Connecting to DC Power
A special IEC 60320 adapter for -48/-60 VDC power connection is supplied with
the unit.
³ To connect to DC power:
• Refer to the DC power supply connection supplement for instructions how to
wire the DC cables. The DC supplement is provided on the technical
documentation CD supplied with the unit.
Warning