Specifications
Installation and Operation Manual Chapter 2 Installation and Setup
Optimux-34 Ver. 2.81 20B19BConnecting to Optimux-34 2-3
Table
2-1. List of Optimux-34 Modules
Module Designation Fixed/
Optional
Location Used to provide
E3 unbalance (coax) Link Optional Front slots LINK A/B Unbalanced interface to the link.
E3 fiber optic Link Optional Front slots LINK A/B Fiber optic interface to the link.
Power supply–PWR-A Optional On the front side Optimux-34 supply voltages
Power supply–PWR-B Optional On the front side Power supply redundancy - power
consumption sharing or full consumption in
case of power supply A failure.
If the 16 E1 unbalanced interface option is needed, order the 2U Optimux-34.
If there is not enough space for the 2U-high device, the 1U device can be used
with the RJ-45 to BNC adapter cable (CBL-RJ45/2BNC/E1/X) and 2 BNC cables for
each channel.
2.6 Connecting to Optimux-34
The E1, USER Ethernet, MNG Ethernet, V.35 interface, alarm, power supplies,
tributary and link connectors are all located on the front panel of the unit as
shown in the following figures. Front panel LEDs indicate system and link status.
The management, alarm, and link connectors are detailed in
Table
2-2
.
The rear panel of the Optimux-34 unit is blank. All connectors are located on the
front panel.
Figure
2-1. Typical 1U-high Front Panel with Optional Alarm and V.35 Connectors
Figure
2-2. Typical 2U-high Front Panel with Optional Alarm and V.35 Connectors
Note