Specifications
Optimux-34 Ver. 2.81 Package Contents 2-1
Chapter 2
Installation and Setup
Optimux-34 is delivered completely assembled. It is designed for installation as a
desktop unit or for mounting on a 19-inch rack. For rack installation instructions,
refer to the
Rack Mounting Kit for 19-inch Racks Guide
that comes with the RM kit.
After installing the unit, refer to the
Chapter 3
for system operating instructions. In
case a problem arises, refer to the
Chapter 5
for test and diagnostics instructions.
No replacement of cards and cables or other repairs may be performed by either
the operator or the user. Such activities may be performed only by a skilled
technician who is aware of the hazards involved.
Always observe standard safety precautions during installation, operation, and
maintenance of this product.
Before installing the product, review
Handling Energized Products
in the Front
Matter of the manual.
2.1 Site Requirements and Prerequisites
Optimux-34 units should be installed within 1.5m (5 ft) of an easily accessible
grounded outlet for a hot-swap wide-range universal PS15 AC/DC power supply.
The input voltage at the end of the power cable 100 to 240 VAC and -40 to -72
VDC, should be within these limits.
Allow at least 90 cm (36 in) of frontal clearance for operator access.
When planning the routing of fiber optic cables, avoid sharp bends. The bending
radius should exceed 30 mm (1.2 in).
The ambient operating temperature of Optimux-34 should be 0°C to 50°C
(32°F to 122°F) at a relative humidity of up to 90%, non-condensing.
2.2 Package Contents
A preliminary inspection of the equipment contained in the shipping box should
be made before unpacking. Evidence of damage should be noted and reported
immediately. The Optimux-34 package includes the following items:
• Optimux-34 unit
• Technical Documentation CD
Warning
Note