Specifications

Installation and Operation Manual Chapter 1 Introduction
Optimux-34 Ver. 2.81 Technical Specifications 1-11
User Ethernet Port
Physical Interface
10/100BaseT
Data Rate
10/100 Mbps
Transmission Mode
Full/half-duplex
Autonegotiation enable/disable
Multicast frames enable/disable
Flow Control and Backpressure enable/disable
Bridge Parameters
Data transfer rate: up to 32 Mbps maximum
2K supported addresses
Supported frame size: up to 1536 bytes
Throughput: up to 60,386 pps (32 Mbps
data transfer rate, 64-byte frames)
Latency: 30 μsec (32 Mbps data transfer
rate, 64-byte frames)
Compatible with IEEE 802.3, 802.3x, 802.3u,
802.1p and 802.1q (802.1D relevant parts)
Fault propagation in LAN in case of WAN
error (optional)
Connector: RJ-45
Power
Number of Supplies
One or two (power sharing)
Power Supply
100-240 VAC, 0.25A
or
-48 VDC, 0.35A
Power Consumption
AC: 32 VA max
DC: 13W max
Unit Indications
and Alarms
Unit Indications
See
Table 3-1.
Dry Contacts
Maximum Ratings: 1A, 60 VDC, 30 VAC
Major alarms: Power off; E1 loss of signal; E3
loss of frame on the active link; E3 loss of
signal on the main link; E3 loss of signal on
the backup link in Automatic/Manual
redundancy mode; backup link does not
install in Automatic/Manual redundancy mode.
In redundant power supply mode: one power
supply is faulty; self-test fail.
Minor alarm: Power off, AIS on E1 input line,
AIS on link input
Connector: 9-pin D-type female