Specifications

Quick Start Guide Installation and Operation Manual
2 Configuring Optimux-34 Optimux-34 Ver. 2.81
2. Connecting the Power
Before connecting or disconnecting any communication cable, the unit must be
earthed by connecting its power cord to a power outlet with an earth terminal,
and by connecting the earth terminal on the panel (if provided) to a protective
earth.
Any interruption of the protective (grounding) conductor (inside or outside the
instrument) or disconnecting of the protective earth terminal can make this unit
dangerous. Intentional interruption is prohibited.
Connecting to AC Power
AC power is supplied to the Optimux-34 through a standard 3-prong plug.
AC power should be supplied via a 1.5m (5 ft) standard power cable terminated
by a standard 3-prong socket. A cable is provided with the unit.
³ To connect to AC power:
1. Connect the power cable to the power connector on the Optimux-34 front
panel.
2. Connect the power cable to the mains outlet.
The unit will turn on automatically upon connection to the mains.
Connecting to DC Power
A special IEC 60320 adapter for -48/-60 VDC power connection is supplied with
the unit.
³ To connect to DC power:
Refer to the DC power supply connection supplement for instructions how to
wire the DC cables. The DC supplement is provided on the technical
documentation CD supplied with the unit.
The DC installation procedure must be performed by a qualified technician.
3. Configuring Optimux-34
Configure Optimux-34 to the desired operation mode via an ASCII terminal
connected to the front panel CONTROL port. The initial configuration of
Optimux-34 includes selection of the clock source and the link redundancy.
Warning
Caution