Specifications

Chapter 5 Monitoring and Diagnostics Installation and Operation Manual
5-10 Handling Events Optimux-108 Ver. 6.1
Optimux-108
Monitoring>System>Event Log
Source Alarm Status Severity
1 Local Device Remote connection fail ON MAJOR
2 Local Device PS B fail ON MAJOR
| 3 Local MNG-ETH ETH Integrity fail ON MAJOR
v 4 Local USER-ETH ETH Integrity fail ON MAJOR
5 Local Device Redundancy not available ON MAJOR
6 Local Ch-1 Signal Loss ON MAJOR
7 Local Ch-2 Signal Loss ON MAJOR
8 Local Ch-3 Signal Loss ON MAJOR
9 Local Ch-4 Signal Loss ON MAJOR
10 Local Device Remote connection fail OFF MAJOR
->>
ESC-prev.menu; !-main menu; &-exit; ?-help 1 Mngr/s
Figure
5-9. Event Log
The log displays the source of the event, alarm indicated as the result of the
event, its status (ON, OFF, NA) and severity (Major Alarm, Minor Alarm or Event).
The Optimux-108 events are described in
Table
5-7
.
Table
5-7. Optimux-108 Events
Code Event Description
100 Software process failed Failed to process software download.
101 Buffer overflow The event log buffer exceeded its maximum
size and new events are written over the old
ones.
102 Local login Login was performed to the PUT.
103 Invalid Login Login to the PUT with wrong user name or
password.
104 SNMP authentication failure Read/write via SNMP with wrong community
105 Cold Start Power up event
106 Link Switch Switch between Link A to Link B
Clearing Events
³ To clear the event log:
1. From the System Log menu, select Clear Log File.
A confirmation message appears.
2. Enter Yes to clear the event log buffer.