Specifications
Chapter 5 Monitoring and Diagnostics Installation and Operation Manual
5-8 Detecting Problems Optimux-108 Ver. 6.1
5.2 Detecting Problems
Front Panel LEDs
The status of Optimux-108 is indicated by the Link A and B, CH1 to CH4 and
power supply LED indicators located on the front panel. For the description of
LEDs and their functions, refer to
Chapter 3
.
Alarms and Traps
Optimux-108 detects fault conditions and initiates alarms and events to alert the
user:
• Alarms (major and minor) have two statuses: ON and OFF. The alarm status
automatically changes to OFF when a fault condition that triggered the alarm
is cleared.
• Events have only ON status.
Handling events and alarms is done via the System Monitoring menu (shown in
Figure
5-8)
and described in the following sections.
Optimux-108
Monitoring>System
MAC Address (0020D222E15F)
Sys Up Time ... (0 days 05:06:34)
1. Active Alarms []
2. Event Log []
3. Status >
4. Interface Status []
5. Clear Log File
>
Please select item <1 to 5>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
5-8. System Monitoring Menu
Optimux-108 maintains a separate log files for events and active alarms.
Optimux-108 supports SNMP traps for the following events:
Cold start
Link up
Link down
Authentication failure
TFTP status change
Agent status change
Line status change
Power status change