Specifications

Installation and Operation Manual Chapter 4 Configuration
Optimux-108 Ver. 6.1 Performing Additional Tasks 4-21
³ To monitor the status of the E1 port:
1. To toggle between the local and remote device, enter 1.
The Device Number changes to identify the unit currently being
monitored (Local or Remote).
2. To select an E1 port to monitor, enter 2 and then the port number (1 to 4).
The screen displays the current status of the selected port on the
selected device.
V.35 Port
Optimux-108
Monitoring>Physical Layer>V.35
1. Device Number > (Local)
Administrative Status > (Up)
Operation > (Down)
Alarm Indication > (Signal loss)
Test Indication > (Off)
Alarm > (Unmasked)
>
Please select item <1 to 1>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
4-27. V.35 Port Status Screen
Table
4-9. V.35 Status Parameters
Parameter Possible Values Description
Device Number Local
Remote
Identifies the device currently being
monitored
Administrative Status Up
Down
Identifies if DTE is connected to the
V.35 port
Operation Up
Down
Indicates the current operational
status of the device
Alarm Indication Normal
Signal loss
Indicates the highest status level of
current alarms
Test Indication On
Off
Indicates whether a loopback test is
currently being run
Alarm Masked
Unmasked
Identifies whether or not an alarm on
the device is masked. When masked, a
V.35 alarm is not trapped. If a
Telebras cable is connected, the alarm
should be masked.
³ To monitor the status of the V.35 port:
To toggle between the local and remote device, enter 1.