Specifications

Chapter 4 Configuration Installation and Operation Manual
4-16 Performing Additional Tasks Optimux-108 Ver. 6.1
Displaying the System Status
The System Status screen displays the current status of the local or remote
Optimux-108 units.
Table
4-7
lists the values and the meaning of these
parameters.
Optimux-108
Monitoring>System>Status
1. Device Number > (Local)
Device Type > (Optimux-108)
Force Link > (LINK A)
Active Link > (LINK A)
Redundancy Status > (Available)
Redundancy Mode > (Auto)
PS A status > (OK)
PS B status > (OK)
Alarm Indication > (Major)
Test Indication > (Off)
>
Please select item <1 to 1>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
4-20. System Status Screen
Table
4-7. System Status Parameters
Parameter Description
Device Number
Indicates the Optimux-108 currently being monitored:
Local
Remote
Device Type Displays the device type
Redundancy Status Indicates if redundancy is available or not available
Available – two uplinks are installed
Not Available – only one uplink is installed, or Redundancy
mode is ‘OFF’
Redundancy Mode The redundancy state of the system:
Auto
Manual
Off
The option is hidden when redundancy status is not available.
Force Link Indicates the main uplink
Active link Identifies the currently active link
PS A Status The state of Power Supply A:
OK
Fault
Not mounted (in case only one PS has been ordered – PS B)