Specifications

Installation and Operation Manual Chapter 4 Configuration
Optimux-108 Ver. 6.1 Performing Additional Tasks 4-15
You can monitor the following aspects of the Optimux-108 system:
System up-time
MAC address
Alarms and events
Interface status
The System Monitoring menu screen is shown in
Figure
4-18
.
Table
4-6
explains
the System Monitoring parameters.
Optimux-108
Monitoring>System
MAC Address (0020D222E15F)
Sys Up Time ... (0 days 05:06:34)
1. Active Alarms []
2. Event Log []
3. Status >
4. Interface Status []
5. Clear Log File
>
Please select item <1 to 5>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
4-19. Monitoring Menu
Table
4-6. System Monitoring Parameters
Parameter Description
MAC Address The address the device holds when transmitting frames
via the Ethernet port.
Sys Up Time Elapsed time since system was powered up.
Active Alarms Displays active alarms on a local and remote devices,
their severity (Major or Minor) and status (Masked or
Unmasked). For description of Active Alarms screen, refer
to
Chapter 6
.
Event Log Displays the events logged by the system. Displays the
source of the event, alarm indicated as the result of the
event, its status (ON, OFF, NA) and severity (Major, Minor
or Event). It can be maximum 200 entries to the log file.
For description of Event Log screen, refer to
Chapter 6
.
Status Displays the detailed system status
Interface Status Displays the current interface status (UP, DOWN, NA),
type and speed for all the interfaces
Clear Log File Clears the log file