Specifications

Installation and Operation Manual Chapter 4 Configuration
Optimux-108 Ver. 6.1 Configuring Optimux-108 for Operation 4-11
Optimux-108
Configuration>Physical Layer>V.35
1. Device Number > (Local)
2. Administrative status (Up)
3. Port Name ... ()
4. Clock Source > (Internal)
5. DCD Status > (Permanent ON)
6. CTS Status > (Permanent ON)
7. DTE Loop Detection > (Disable)
8. Alarms (Unmasked)
>
Please select item <1 to 8>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
4-14. V.35 Menu
Table
4-4. V.35 Parameters
Parameter Possible Value Description
Device Number Local
Remote
Identifies whether parameters
shown are for the local or remote
device.
Administrative
status
UP
Down
Identifies whether interface is Up or
Down. In case it is down, all other
parameters are not displayed
Port Name String of up to 15 characters
Default: Null
A name to easily identify this uplink
port.
Clock Source Internal
LBT
External
Identifies whether V.35 interface
clock is internal, LBT (Loop back
timing) or External
DCD Status Permanent ON
Controll
Identifies whether DCD (Data Carrier
Detect) is permanently set to ON or
it is set to ON only when there is no
signal failure in the active link.
CTS Status Permanent ON
Controll
Identifies whether CTS (Clear to
Send) is permanently set to ON or it
is set to ON only when RTS (Request
to Send) is ON.
DTE Loop
Detection
Disable
Enable
Identifies whether DTE is able to set
LLB loop on V.35 interface.
Disable – LLB loop is not applied.
Enable – LLB is applied