Specifications
Chapter 4 Configuration Installation and Operation Manual
4-10 Configuring Optimux-108 for Operation Optimux-108 Ver. 6.1
Parameter Possible Value Description
Alarms Masked
Unmasked
Identifies whether alarms triggered by this
port are masked or not. When masked,
these alarms are not trapped and are not
recorded in the log file.
Configuring Uplink Parameters
³ To configure uplinks:
• From the Main menu, choose Configuration>Physical Layer>Link.
Optimux-108
Configuration>Physical Layer>Link
1. Device Number > (Local)
2. Port number > (LINK A)
3. Port Name ... ()
4. Alarms > (Unmasked)
>
Please select item <1 to 4>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
4-13. Link Menu
Table
4-3. Uplink Parameters
Parameter Possible Value Description
Device Number Local
Remote
Identifies whether parameters
shown are for the local or remote
device.
Port number LINK A or LINK B Identifies the uplink port to
configure.
Port Name String of up to 15 characters
Default: Null
A name to easily identify this uplink
port.
Alarms Masked
Unmasked
Identifies whether alarms triggered
by this port are masked or not.
When masked, these alarms are not
trapped and are not recorded in the
log file.
Configuring V.35 Parameters
The following menu is used to configure parameters of the optional V.35
interface.