Specifications
Installation and Operation Manual Chapter 4 Configuration
Optimux-108 Ver. 6.1 Configuring Optimux-108 for Operation 4-9
The System Configuration menu opens. The alarm forwarding option is
disabled by default.
Optimux-108
Configuration>System
1. Management >
2. Control Port >
3. Fault Propagation (Off)
4. Alarms >
5. Redundancy >
6. Factory Default >
>
Please select item <1 to 6>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
4-11. System Configuration Menu
2. Type 3 to enable alarm forwarding:
When signal loss or sync loss is detected on the uplink, the USER-ETH
port on both (local and remote products) is shut down.
When the USER-ETH port detects that the link is down, the USER-ETH port
on the remote product is automatically shut down.
Configuring E1 Channel Parameters
The following menu is used to configure the E1 ports.
Optimux-108
Configuration>Physical Layer>E1
1. Device Number > (Local)
2. Port number [1-4] > (1)
3. Port Name ... ()
4. Alarms > (Unmasked)
>
Please select item <1 to 4>
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s)
Figure
4-12. E1 Configuration Screen
Table
4-2. E1 Channel Parameters
Parameter Possible Value Description
Device Number Local
Remote
Identifies whether parameters shown are
for the local or remote device.
Port number 1 to 4 Identifies the E1 port to configure.
Port Name String of up to 15
characters
Default: Null
A name to easily identify this E1 port.