Specifications

Installation and Operation Manual Chapter 4 Configuration
Optimux-108 Ver. 6.1 Configuring Optimux-108 for Operation 4-7
Optimux-108
Configuration>Physical Layer>Ethernet
1. Device Number > (Local)
2. Port number > (MNG-ETH)
3. Port Name . . . ()
4. Auto Negotiation > (Enabled)
5. Flow Control > (Enabled)
6. Alarms > (Unmasked)
>
Please select item <1 to 6>
ESC-Previous menu; !-Main Menu; &-Exit 1 user(s)
Figure
4-8. Ethernet Menu (Management Port)
In the Optimux-108 with Ethernet user port, the Ethernet menu may display the
configuration for ETH-USER port. To toggle between configurations, select Port
Number and the Port Number Menu appears (
Figure
4-9
).
2. Select Device Number to set the device location (local or remote).
3. Select Port Number to set the Fast Ethernet port number to ETH-MNG.
4. Select Auto Negotiation to toggle between the Enabled and Disabled options.
5. Select Flow Control to toggle between the Enabled and Disabled options.
6. Select Alarms to mask or unmask the Fast Ethernet alarms. This option
identifies whether alarms triggered by this Ethernet port are masked or not.
When masked, these alarms are not trapped and are not recorded in the log
file.
4.2 Configuring Optimux-108 for Operation
The recommended configuration procedure for Optimux-108 includes the
following stages:
1. Configuring device-level parameters (link protection)
2. Configuring the uplink, tributary and user interfaces at the physical level.
Configuring the Ethernet User Port
³ To configure the Ethernet User port:
1. From the Ethernet menu (
Figure
4-8
), select Port Number.
The Port Number menu opens.